دسته بندی ها
کاربر سایت شوید
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Kabel & Leitungen
تایپ کالا
:
E90 -J 3X50RM/25RM
ویژگیها
Ladders
Copper
Lamp surface
blank
Lead cross section
50 mm ²
AWG size
1
Lead cross section (AWG)
1
Ladders_2
Cl.2 = multi-wire
قیمت
:
استعلام
حداقل قابل خرید
:
100 متر
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
Lapp SKINTOP Series Metallic Stainless Steel Cable Gland, M16 Thread, 5mm min., 7mm max., IP69K
Roline, 3m Cat6a, Blue RJ45 to Male RJ45 Male, U/UTP Unshielded, Terminated LSZH Sheath
TE Connectivity Heat Shrink Tubing, Brown 19mm Sleeve Dia. x 1.2m Length 2:1 Ratio, RNF-100 Series
Lutronic Male 8 way M8 to Female 8 way M8 Industrial Automation Cable Assembly, 2 m
Energy cable > = 1 kV, for fixed installation
Halogenfree safety cable, orange (N) HXH E 90 0.6 / 1 kV. Isolation content over 180 minutes according to DIN VDE 0266, function maintenance > 90 minutes according to DIN 4102 part 12. Structure: copper conductor blank, single-wire or multi-wire, according to DIN VDE 0295 / 5.86 Class 1 or 2 conductor coating made of overlapping mineral handling. Insulating case of connected flame-resistant polyethylene copolymerisate mixed type 3GI10 and according to the requirement of the mixing type HI1 according to DIN VDE 0207 part 23. - Flame protection, - joint anterior coating,, compressed or wrapped separator, - outer coat of polyolefins copolymerisate. Mixing type THP and according to the requirement for mixing type HM4 according to DIN VDE 0207 Part 24. Use: For fixed laying, in dry, wet and wet rooms above, on, in and under plaster, as well as in the masonry and concrete. They are also suitable for outdoor and ground use when laid in pipes. In addition, DIN VDE 0298 parts 1 and 2 apply. Permissible operating temperature on the ladder + 90 ° C. The cables meet the conditions of the insulation maintenance test according to DIN VDE 0472 Part 814 / 8.83 over 180 minutes and IEC Publication 331 first edition 1970. Maintenance > 90 minutes according to DIN 4102 part 12, according to VDE 0107 and 0108. Note: According to VDE 0276 part 604, the cross-section of the conductor can be made 16 mm ² as RE (round - single-wire) or RM (round - multi-wire). Metal number (copper): 168,000 per 100 meterThe metal number is a purely commercial calculation size and may differ from the actual metal weight, although usually expressed in kg / km in industry.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
E90 -J 3X50RM / 25RM, Eucasafe NHXH FE180 E90
قیمت
:
استعلام
حداقل قابل خرید
:
100 متر
قابل پرداخت
:
استعلام