دسته بندی ها
کاربر سایت شوید
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Kabel & Leitungen
تایپ کالا
:
10554
کد سازنده
:
10554
ویژگیها
Tariff number
85444995
Ader number
4
External diameter approx.
7.1 mm
Fire behaviour according to EN 13501-6: class
Eca
Ladders
Cl.5 = hostile
Lead cross section
0.5 mm ²
قیمت
:
استعلام
حداقل قابل خرید
:
100 متر
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
RS PRO Armoured 10 mm² 4 Core Power Cable, Black PVC, 50m
Alpha Wire Ecogen Ecocable Mini Control Cable, 6 Cores, 0.15 mm² 26 AWG, Unscreened, 30 m, Grey Modified Polyphenylene
Belden 9501 Series Data Cable, 1 Pairs, 2 Cores, 0.25 mm², Screened, 24 AWG, 305m, Screened Shield
RS PRO Male SVHS to Male SVHS Black DIN Cable 7.5m
Energy cable < 1 kV, for mobile use
Technical data: Special PVC control line for locking technology based on DIN VDE 0285-525-2-51 / DIN EN 50525-2-51 temperature range moving -15 ° C to + 80 ° C not moving -40 ° C to + 80 ° C nominal voltage U0 / U 300 / 500 V test voltage 4000 V flow voltage min. 8000 V isolation resistance min. 20 MOhm x km minimum bending radius moves 7,5x line Ø not moving 4x line Ø radiation resistance up to 80x106 cJ / kg (up to 80 Mrad) structure: Cu-Litze blank, according to DIN VDE 0295 Kl5, enemy-tanned, BS 6360 cl.5, IEC 60228 cl.5 Aderisation from special -PVC Aderisation from special -Ader marking according to DIN VDE 0293 orange veins with continuous black dial pressure, with optimal impact length in the case of the outer surface: PVC - resistant to the external surface: The materials used in the production are silicone and cadmium-free and free of paint-wetting substances testing: PVC self-extinguishing and flame-resistant according to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2: is used as a control line according to DIN EN 6020-1 and is used in the case of medium mechanical use for flexible application with free movement without stress and without forced movement in dry, wet and wet spaces, but not outdoors, as a control line according to DIN EN 60204-1 or VDE 0113-1. In accordance with the above-mentioned standard, it is recommended that isolated conductors of locking circuits fed by an external energy supply remain under voltage when the main switch is switched off to mark orange. Control lengths: 50 m, 100 m, 500 m, 1000 m Technical changes reserved. Metal number (copper): 1.900 per 100 meterThe metal number is a purely commercial calculation size and may differ from the actual metal weight, although usually expressed in kg / km in industry.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
10554, HELUKABEL PVC control line OZ-600 4x0.5 mm ² Black
قیمت
:
استعلام
حداقل قابل خرید
:
100 متر
قابل پرداخت
:
استعلام