دسته بندی ها
کاربر سایت شوید
تابلو و توزیع برق
/
پشتیبان گیری مواد
/
شکستن مدار برای ترانسفورماتور، ژنراتور و حفاظت از سیستم
/
HMT160GR
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Hager
تایپ کالا
:
HMT160GR
کد سازنده
:
HMT160GR
کد EAN
:
3250613176518
ویژگیها
Rated current
160 A
With undervoltage trigger
No
Number of help contacts as changers
0
Number of help contacts as opener
0
Set range of the immediate short-circuit trigger
1,760... 1,760 A
Overload power setting
57.3... 160 A
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
WK 2.5-4 COI / U-PGN / V0, initiator clamp-WK 2.5-4 COI / U-PGN / V0
TK PC 2518-13f-m, empty housing, protection type IP66, impact resistance IK08, protection class II, Ui 690V AC, measurement insulation voltage 1000V DC, UL, DLG, DNV, halogen-free
8US1998-1CA00, collection rail system, accessories rail centre distance 40, 60mm screw holder
KYB16E, protective conductor terminal 16mm ²
= = References = = h3 + P250 LSnI 3x160A 50kA
H3 + P250 LSnI 3P3D 160A 50kA FTC.The compact power switch in accordance with DIN EN 60947-2 protects the electrical system and networks from overload and short circuit. The trigger curve of the electronic trigger can be set by means of a rotary rest switch. The trigger for the overload current (Ir) and the short-term short-circuit current (Isd) can be separated. The immediate trigger for the short circuit current Ii is fixed. A ready-to-use LED lights green when the trigger is ready for use and blinks orange when an internal error is detected in the trigger. Another LED starts to flash red when I = 105% Ir, and lights permanently red when I 112% Ir. At the position of the slave the three different operating states are visible (one = above, OFF = below, triggered = middle position). A device for locking the switching state in ON or off position is integrated and can be used with a commercial padlock without additional accessories. A trigger key can be used to test the trigger emanism and open the main contacts. A folding cap with an unlegible quick screw allows access to the installation room for optional help contacts and other triggers. Integrated accessories can be identified and identified via the view window without opening the folding cover. The set trigger curve can be tested and documented by means of an interface for a diagnostic and configuration tool.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
HMT160GR, benefit. h3 + P250 LSnI 3x160A 50kA
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام