دسته بندی ها
کاربر سایت شوید
تابلو و توزیع برق
/
پشتیبان گیری مواد
/
شکستن مدار برای ترانسفورماتور، ژنراتور و حفاظت از سیستم
/
HNT100GR
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Hager
تایپ کالا
:
HNT100GR
کد سازنده
:
HNT100GR
کد EAN
:
3250613176693
ویژگیها
Overload power setting
36.4... 100 A
Type of protection (IP)
IP40
Set range of short-term delayed short-circuit trigger
54.6... 1,000 A
Engine drive optional
Yes
Device type
Fixed installation equipment
Number of help contacts as close
0
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
OHYS2AJ, OHYS2AJ Selectric handle I-0 / ON-OFF red-yellow wave-ø 6mm IP65 for load separation
3VA2125-8HK46-0AA0, power switch 3VA2 IEC Frame 160 switching power class L Icu = 150kA @ 415V
T3-3-8342 / I2 / SVB, main switch, T3, 32 A, structure, 3 construction unit (s), 6-pole, NOx-off function, with red swivel handle and yellow barrier, lockable in 0 position
209-813, labeling strand G print horizontal white
= = References = = h3 + P250 LSnI 3x100A 40kA
H3 + P250 LSnI 3P3D 100A 40kA FTC.The compact power switch in accordance with DIN EN 60947-2 protects the electrical system and networks from overload and short circuit. The trigger curve of the electronic trigger can be set by means of a rotary rest switch. The trigger for the overload current (Ir) and the short-term short-circuit current (Isd) can be separated. The immediate trigger for the short circuit current Ii is fixed. A ready-to-use LED lights green when the trigger is ready for use and blinks orange when an internal error is detected in the trigger. Another LED starts to flash red when I = 105% Ir, and lights permanently red when I 112% Ir. At the position of the slave the three different operating states are visible (one = above, OFF = below, triggered = middle position). A device for locking the switching state in ON or off position is integrated and can be used with a commercial padlock without additional accessories. A trigger key can be used to test the trigger emanism and open the main contacts. A folding cap with an unlegible quick screw allows access to the installation room for optional help contacts and other triggers. Integrated accessories can be identified and identified via the view window without opening the folding cover. The set trigger curve can be tested and documented by means of an interface for a diagnostic and configuration tool.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
HNT100GR, benefit. h3 + P250 LSnI 3x100A 40kA
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام