دسته بندی ها
کاربر سایت شوید
تابلو و توزیع برق
/
پشتیبان گیری مواد
/
شکستن مدار برای ترانسفورماتور، ژنراتور و حفاظت از سیستم
/
HMS101GC
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Hager
تایپ کالا
:
HMS101GC
کد سازنده
:
HMS101GC
کد EAN
:
3250613145750
ویژگیها
Type of protection (IP)
IP40
Number of help contacts as changers
0
Number of help contacts as opener
0
Complete unit with protection unit
Yes
Operation element execution
Kneel
Engine drive optional
No
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
3VA1032-4ED32-0DH0, power switch 3VA1 IEC Frame 100 switching power class S Icu = 36kA @ 415V 3.
3VA2340-6JP32-0AE0, power switch 3VA2 IEC Frame 400 switching power class H Icu = 85kA @ 415V 3-pole, system protection ETU550, LSI, In = 400A overload protection Ir = 160A... 400A
5SD606, diazed fuse 20A, 750V, E33 flink DC-line protection
3VA2163-7HN32-0AC0, power switch 3VA2 IEC Frame 160 switching power class C Icu = 110kA @ 415V 3-pole, system protection ETU350, LSI, In = 63A overload protection Ir = 25A... 63A Ku
= = References = = h3 + P160 LSnI 4x100A 50kA
H3 + P160 LSnI 4P4D N0-50-100% 100A 50kA CTC.The compact power switch in accordance with DIN EN 60947-2 protects the electrical system and networks from overload and short circuit. The trigger curve of the electronic trigger can be set by means of a rotary rest switch. The trigger for the overload current (Ir) and the short-term short-circuit current (Isd) can be separated. The immediate trigger for the short circuit current Ii is fixed. The neutralconductor protection can be adjusted with a controller to the position OFF, 50% of Ir and Isd or 100% of Ir and Isd. The time delay remains as with tr and tsd. A ready-to-use LED lights green when the trigger is ready for use and blinks orange when an internal error is detected in the trigger. Another LED starts to flash red when I = 105% Ir, and lights permanently red when I 112% Ir. At the position of the slave the three different operating states are visible (one = above, OFF = below, triggered = middle position). A device for locking the switching state in ON or off position is integrated and can be used with a commercial padlock without additional accessories. A trigger key can be used to test the trigger emanism and open the main contacts. A folding cap with an unlegible quick screw allows access to the installation room for optional help contacts and other triggers. Integrated accessories can be identified and identified via the view window without opening the folding cover. The set trigger curve can be tested and documented by means of an interface for a diagnostic and configuration tool.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
HMS101GC, performance. h3 + P160 LSnI 4x100A 50kA
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام