دسته بندی ها
کاربر سایت شوید
تابلو و توزیع برق
/
پشتیبان گیری مواد
/
شکستن مدار برای ترانسفورماتور، ژنراتور و حفاظت از سیستم
/
HNS041GC
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Hager
تایپ کالا
:
HNS041GC
کد سازنده
:
HNS041GC
کد EAN
:
3250613145835
ویژگیها
With trigger detector
Yes
Engine drive integrated
No
Overload power setting
14.6... 40 A
Integrated ground closure protection
No
Operation element execution
Kneel
Icu at 400 V, 50 Hz
40 kA
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
F9-2000-2011, universal security holder
280-833, 4-conductor through terminal 2.5 mm ² grey
3VA2163-7HN32-0AB0, power switch 3VA2 IEC Frame 160 switching power class C Icu = 110kA @ 415V 3-pole, system protection ETU350, LSI, In = 63A overload protection Ir = 25A... 63A Ku
XT4N 250 TMF 100-1000 3p F UL / CSA, XT4N 250 TMF 100-1000 3p F UL / CSA Compact power switch Tmax XT4
= = References = = h3 + P160 LSnI 4x40A 40kA
H3 + P160 LSnI 4P4D N0-50-100% 40A 40kA CTC.The compact power switch in accordance with DIN EN 60947-2 protects the electrical system and networks from overload and short circuit. The trigger curve of the electronic trigger can be set by means of a rotary rest switch. The trigger for the overload current (Ir) and the short-term short-circuit current (Isd) can be separated. The immediate trigger for the short circuit current Ii is fixed. The neutralconductor protection can be adjusted with a controller to the position OFF, 50% of Ir and Isd or 100% of Ir and Isd. The time delay remains as with tr and tsd. A ready-to-use LED lights green when the trigger is ready for use and blinks orange when an internal error is detected in the trigger. Another LED starts to flash red when I = 105% Ir, and lights permanently red when I 112% Ir. At the position of the slave the three different operating states are visible (one = above, OFF = below, triggered = middle position). A device for locking the switching state in ON or off position is integrated and can be used with a commercial padlock without additional accessories. A trigger key can be used to test the trigger emanism and open the main contacts. A folding cap with an unlegible quick screw allows access to the installation room for optional help contacts and other triggers. Integrated accessories can be identified and identified via the view window without opening the folding cover. The set trigger curve can be tested and documented by means of an interface for a diagnostic and configuration tool.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
HNS041GC, performance. h3 + P160 LSnI 4x40A 40kA
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام