دسته بندی ها
کاربر سایت شوید
تابلو و توزیع برق
/
پشتیبان گیری مواد
/
شکستن مدار برای ترانسفورماتور، ژنراتور و حفاظت از سیستم
/
3RV2742-5AD10
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Siemens
تایپ کالا
:
3RV2742-5AD10
کد سازنده
:
3RV27425AD10
کد EAN
:
4047621014449
ویژگیها
Complete unit with protection unit
Yes
Engine drive optional
No
Operation element execution
Kneel
Position of connection for main circuit
other
Type of protection (IP)
IP20
Engine drive integrated
No
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
C25V4TM200, compact power switch ComPacT NSX250HB1 with TM200D 4P4D 200 A, 75kA / 690V AC
SAKC 4 / 35, separation and measurement line clamp, screw connection, medium yellow, 4 mm ², 25 A, 400 V, number of connections: 2, number of floors: 1, TS 35, V-0, 5VA, KrG
FWB34A, field distributor AP, univers, 4x3 rows
7P.23.8.275.1020, SPD type 2, 3-phase, varistors, FM
Circuit breaker, S3, plant protection, UL 489, CSA C22.2 No.5-02, N-Ausl. 150 A
Circuit breaker S3 for system protection with application circuit breaker UL 489, CSA C22.2 No.5-02 A trigger 10 A N- trigger 150 A screw connection circuit breaker SIRIUS 3RV2 for system protection according to UL 489 / CSA C22.2 No.5 for short circuit protection of systems and consumers in systems designed according to UL. The compact and climate-resistant circuit breakers are optimized by their low waste heat for use in consumer branches, of course also for IE3 / IE4 engines. Worldwide approvals (e.g. IEC and UL / CSA) and applications in potentially explosive applications (ATEX or IEC Ex) are natural. The range of devices available for engine protection (also with overload relay function), system protection, short-circuit protection of starter combinations, transformer protection, as main and NOT switch and for use in IT networks. They are available with screw or spring connection for a fast, maintenance-free and brittle-proof connection, and optionally with built-in auxiliary switch. The comprehensive accessories, such as auxiliary switches, auxiliary triggers, reporting switches, etc., are uniform for all sizes. The use of different energy supply possibilities, such as the associated SIRIUS 3RV29 feed system, significantly reduces the main current circuit wiring. The 3RV2 circuit breakers release the proven 3RV1 series. Simple, efficient, always up to date - the SIRIUS system kit.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
3RV2742-5AD10, circuit breaker, S3, plant protection, UL 489, CSA C22.2 No.5-02, N-Ausl. 150 A
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام