دسته بندی ها
کاربر سایت شوید
تابلو و توزیع برق
/
پشتیبان گیری مواد
/
شکستن مدار برای ترانسفورماتور، ژنراتور و حفاظت از سیستم
/
3RV2811-0JD10
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Siemens
تایپ کالا
:
3RV2811-0JD10
کد سازنده
:
3RV28110JD10
کد EAN
:
4011209767812
ویژگیها
With trigger detector
No
Icu at 400 V, 50 Hz
100 kA
Device type
Fixed installation equipment
Connection type Main circuit
Screw connection
With undervoltage trigger
No
Rated current
1 A
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
SK 3,8 REEL P7,5 WH CIS, marking assembly, marking card
3VA2140-7JQ36-0AA0, power switch 3VA2 IEC Frame 160 switching power class C Icu = 110kA @ 415V
5TT5001-8, INSTA-Schütz 0 / 1 automatic with 1 clasp and 1 opener, contact for AC 230V
5SV3417-6, FI protection switch, 2-pole, type A, In: 80 A, 100 mA, Un AC: 230 V
Circuit breaker, S00 for transformer protection, UL 489, CSA C22.2 No.5-02
Circuit breaker S00 for the transformer protection with the application circuit breaker UL 489, CSA C22.2 NO.5-02 A trigger 1 A N- trigger 21 A screw connection standard circuit breaker SIRIUS 3RV2 for transformer protection according to UL 489 / CSA C22.2 No.5 for short circuit protection of systems and transformers in systems designed according to UL. The compact and climate-resistant circuit breakers are optimized by their low waste heat for use in consumer branches, of course also for IE3 / IE4 engines. Worldwide approvals (e.g. IEC and UL / CSA) and applications in potentially explosive applications (ATEX or IEC Ex) are natural. The range of devices available for engine protection (also with overload relay function), system protection, short-circuit protection of starter combinations, transformer protection, as main and NOT switch and for use in IT networks. They are available with screw or spring connection for a fast, maintenance-free and brittle-proof connection, and optionally with built-in auxiliary switch. The comprehensive accessories, such as auxiliary switches, auxiliary triggers, reporting switches, etc., are uniform for all sizes. The use of different energy supply possibilities, such as the associated SIRIUS 3RV29 feed system, significantly reduces the main current circuit wiring. The 3RV2 circuit breakers release the proven 3RV1 series. Simple, efficient, always up to date - the SIRIUS system kit.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
3RV2811-0JD10, power switch, S00 for transformer protection, UL 489, CSA C22.2 No.5-02
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام