دسته بندی ها
کاربر سایت شوید
تابلو و توزیع برق
/
پشتیبان گیری مواد
/
شکستن مدار برای ترانسفورماتور، ژنراتور و حفاظت از سیستم
/
3RV2811-0HD10
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Siemens
تایپ کالا
:
3RV2811-0HD10
کد سازنده
:
3RV28110HD10
کد EAN
:
4011209767805
ویژگیها
Engine drive optional
No
Icu at 400 V, 50 Hz
100 kA
Measurement voltage _ R
20... 690 V
Engine drive integrated
No
Complete unit with protection unit
Yes
Number of help contacts as close
0
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
3VA1063-3ED42-0JH0, power switch 3VA1 IEC Frame 100 switching power class N Icu = 25kA @ 415V 4.
MINI-PICTOGRAMS MANDATORY, Safety Signs Minipictograms: Comb cards - Mini 2: bidding signs
M9F21232, Multi 9 OEM LS switch C60SP 2-pole 32A B-Char. 10kA 480Y / 277V UL1077
NSYSFN12860P, stand case, electric, PanelSeT SFN, of decarbonised steel, with mounting plate, mounted, 1200x800x600mm, IP55
Circuit breaker, S00 for transformer protection, UL 489, CSA C22.2 No.5-02
Circuit breaker S00 for the transformer protection with the application circuit breaker UL 489, CSA C22.2 NO.5-02 A trigger 0.8 A N- trigger 16 A screw connection standard circuit breaker SIRIUS 3RV2 for transformer protection according to UL 489 / CSA C22.2 No.5 for short circuit protection of systems and transformers in systems designed according to UL. The compact and climate-resistant circuit breakers are optimized by their low waste heat for use in consumer branches, of course also for IE3 / IE4 engines. Worldwide approvals (e.g. IEC and UL / CSA) and applications in potentially explosive applications (ATEX or IEC Ex) are natural. The range of devices available for engine protection (also with overload relay function), system protection, short-circuit protection of starter combinations, transformer protection, as main and NOT switch and for use in IT networks. They are available with screw or spring connection for a fast, maintenance-free and brittle-proof connection, and optionally with built-in auxiliary switch. The comprehensive accessories, such as auxiliary switches, auxiliary triggers, reporting switches, etc., are uniform for all sizes. The use of different energy supply possibilities, such as the associated SIRIUS 3RV29 feed system, significantly reduces the main current circuit wiring. The 3RV2 circuit breakers release the proven 3RV1 series. Simple, efficient, always up to date - the SIRIUS system kit.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
3RV2811-0HD10, power switch, S00 for transformer protection, UL 489, CSA C22.2 No.5-02
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام