جستجوی کالا ...

logo
Picture of ["6SL3546-0FB21-1FB0, SINAMICS G120D CU250D-2 PN-F PP"]

6SL3546-0FB21-1FB0, SINAMICS G120D CU250D-2 PN-F PP

وضعیت

:

موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته

برند

:

Siemens

تایپ کالا

:

6SL3546-0FB21-1FB0

کد سازنده

:

6SL35460FB211FB0

کد EAN

:

4042948661659

ویژگی‌ها

Supports protocol for PROFINET IO

Yes

Depth

118 mm

Supports protocol for DeviceNet

No

Number of HW interfaces serial RS-232

0

Supported protocol for INTERBUS

No

Supports protocol for PROFINET CBA

No

قیمت

:

استعلام

حداقل قابل خرید

:

1 عدد

قابل پرداخت

:

استعلام

مشاهده جزییات فنی کالا :

معرفی

SINAMICS G120D CU250D-2 PN-F PP

SINAMICS G120D Control Unit CU250D- 2 PN-F PP PROFINET and Safety Integrated Positioning (EPOS) in Push- Pull 6 DI / 3 F-DI, 2 DO / 1 F-DO, 2 AI SD / MMC card interface HTL and SSI Gear Interface Protection Type IP65 Ambient Temperature 0 to + 50 ° C without Power Module Control Unit SINAMS CU250D-2 for the remote inverter SINICS 1G20D. The control unit controls the inverter. In addition to the regulation, other functions are available, which can be adapted to the respective application by appropriate parametrization. With the Control Unit CU250D-2 applications with positioning requirements can be realized in the drive. This extension now allows the use of lifting / turning / driving or turning applications. The positioning functionality is functionally comparable to the S110 servo inverters, but the following instructions must be observed. On the one hand, it is possible to have a vector and a selfless vector, and on the other, it is possible to position it by a donor or in parallel with two donors. The control units are available in different versions in CU250D-2 DP-F, CU250D-2 PN-F, CU250D-2 PN-F PP (Push Pull: alternative connection technology of the DC-24-V supply voltage and PN- communication) and CU250D-2 PN-F FO (Fibre Optic). The Fail-safe inverter SINAMICS G120D offers five security functions with the Fail-safe variants of the entire CU250D-2 series. This is the safe shut-off moment (STO) to protect against active drive movement, safe stop 1 (SS1) for continuous monitoring of a safe brake ramp, a safe limited speed (SLS) to protect against risk-causing movements in the event of exceeding a limit speed, a safe direction of rotation (SDI) and a safe speed monitoring (SSM). An external DC-24-V power supply is required to operate the Control Unit. SINAMICS - the continuous drive family for each application.

مشخصات کالا

دیدگاه کاربران

شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.

دیدگاه خود را ثبت کنید

6SL3546-0FB21-1FB0, SINAMICS G120D CU250D-2 PN-F PP

قیمت

:

استعلام

حداقل قابل خرید

:

1 عدد

قابل پرداخت

:

استعلام