دسته بندی ها
کاربر سایت شوید
تابلو و توزیع برق
/
پشتیبان گیری مواد
/
شکستن مدار برای ترانسفورماتور، ژنراتور و حفاظت از سیستم
/
HEJ400GR
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Hager
تایپ کالا
:
HEJ400GR
کد سازنده
:
HEJ400GR
کد EAN
:
3250613197810
ویژگیها
Rated current
400 A
Polar number
3
With trigger detector
Yes
Engine drive optional
Yes
Connection type Main circuit
Screw connection
Complete unit with protection unit
Yes
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
H7CC@-@ A11S, digital counter, plug-in, 11-pin, 48x48 mm, IP66, 6 count numbers, multifunction: 1-stage and total counter, SPST- transitory output, 100-240- VAC- supply
3VA1132-6EF32-0KC0, power switch 3VA1 IEC Frame 160 switching power class H Icu = 70kA @ 415V 3-pole, system protection TM240, ATAM, In = 32A overload protection Ir = 22A... 32A Kur
3VA2040-5HM36-0AA0, power switch 3VA2 IEC Frame 100 switching power class M Icu = 55kA @ 415V
WQV 4 / 6, cross-connectors (clamps), screwed, yellow, 41 A, poly number: 6, grid in mm: 6.10, isolated: Yes, width: 7.6 mm
. H3 x630 LSnI 3x400A 70kA
Circuit breaker h3 x630 LSnI 3P3D 400A 70kA FTC.The compact power switch in accordance with DIN EN 60947-2 protects the electrical system and networks from overload and short circuit. The trigger curve of the electronic trigger can be set by means of a rotary rest switch. The trigger for the overload current (Ir) and the short-term short-circuit current (Isd) can be separated. The immediate trigger for the short circuit current Ii is fixed. A ready-to-use LED lights green when the trigger is ready for use and blinks orange when an internal error is detected in the trigger. Another LED starts to flash red when I = 105% Ir, and lights permanently red when I 112% Ir. At the position of the slave the three different operating states are visible (one = above, OFF = below, triggered = middle position). A device for locking the switching state in ON or off position is integrated and can be used with a commercial padlock without additional accessories. A trigger key can be used to test the trigger emanism and open the main contacts. A folding cap with an unlegible quick screw allows access to the installation room for optional help contacts and other triggers. Integrated accessories can be identified and identified via the view window without opening the folding cover. The set trigger curve can be tested and documented by means of an interface for a diagnostic and configuration tool.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
HEJ400GR, performance rate h3 x630 LSnI 3x400A 70kA
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام