HPW401NR
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Hager
تایپ کالا
:
HPW401NR
کد سازنده
:
HPW401NR
کد EAN
:
3250613197766
ویژگیها
Measurement voltage _ R
220... 690 V
Connection type Main circuit
Screw connection
Polar number
4
Number of help contacts as close
0
Operation element execution
Kneel
Engine drive integrated
No
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
RKi 4 / 25-L, row clamp housing, protection type IP54 / IP66, max. Lead cross section 4 ², impact resistance IK08, protection class II, Ui 400V AC, halogen-free
LV453427, ComPact NSX1250 NA DC PV Basic switch 1250A, 4P
SV 3590.020, E-Cu 120x10 mm, L = 2400 mm
C11E6TM063B, compact power switch ComPacT NSXm 63A TM63D 4P3D 16kA / 415V
Power. h3 + P630 Energy 4x400A 110kA
H3 + P630 Energy 4P4D N0-50-100% 400A 110kA FTC.The compact power switch in accordance with DIN EN 60947-2 protects the electrical system and networks from overload and short circuit. The trigger curve of the electronic trigger can be set by means of a rotary rest switch. Separated are the trigger for the overload current (Ir), the short-term short-circuit current (Id) and the immediate short-circuit protection (Ii), as well as the time delay for overload and the time delay tsd for short-term short-circuit trigger. In addition, an activated I ² t function can be used to adjust the trigger curve proportionally between the short-circuit flow Ii and Isd and the short-term delayed and undelayed release time. The stand-up LED lights green when the trigger is ready for use and blinks orange when an internal error is detected in the trigger. The LED for the overcurrent display begins to flash red when I = 105% Ir, and lights permanently red when I 112% Ir. Another LED signals the overtemperature in the release unit. This is red when it is exceeded 105 ° C internally. At the position of the slave the three different operating states are visible (one = above, OFF = below, triggered = middle position). A device for locking the switching state in ON or off position is integrated and can be used with a commercial padlock without additional accessories. A trigger key can be used to test the trigger emanism and open the main contacts. A folding cap with an unlegible quick screw allows access to the installation room for optional help contacts and other triggers. Integrated accessories can be identified and identified via the view window without opening the folding cover. A potential-free alarm contact for the switch-off warning at the risk of overload shutdown is integrated by default. This is closed at I 90% Ir. This is shown by an additional LED. It lights up orange when the contact is closed. The set trigger curve can be tested and documented by means of an interface for a diagnostic and configuration tool.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
HPW401NR, power. h3 + P630 Energy 4x400A 110kA
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام