دسته بندی ها
کاربر سایت شوید
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Doepke Schaltgeräte
تایپ کالا
:
DRCBO 4 C25/0,03/3N-A
کد سازنده
:
09945126
کد EAN
:
4014712266414
ویژگیها
Installation depth
68 mm
On-line neutral conductor
Yes
Number of secured poles
3
Fault current type
A
Switching characteristics
without delay
Frequency _ Z
50 / 60 Hz
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
OXB630E3S4QB, OXB630E3S4QB Automatic switch TruONE 3-pole + N 630A level 4 control unit
2200-1404, 4-wire through terminal with 1 mm ² of blue pressure
3VA1225-6GF42-0AB0, power switch 3VA1 IEC Frame 250 switching power class H Icu = 70kA @ 415V 4-pole, system protection TM240, ATAM, In = 250A overload protection Ir = 175A... 250A
20.21.9.012.4000, electric shock switch
Doepke FI / LS combination 3p + N, 25 A, 0.03 A, C-Char.Type A
RCBO combines error current and control switch in one device (FI / LS combination). They protect people from flaws and systems from short circuit and overload. DRCBO 4 has a rated power of 6 kA. In addition to the triggered display, they also offer a label window. Type A switches are pulse and AC sensitive. This function is power independent. Switches with the trigger characteristic C are optimized for circuits with high on or peak currents. Standard switches are for circuits with a measurement voltage of 230 V or 400 V and a rated frequency of 50 Hz. Characteristics: pulse and AC-sensitive, power-independent trigger, low size for all measuring currents, switching position display, separate display of the trigger floor, pull-in terminals with a wide clamp-section area on both sides of the connection, neutral ladder on the right, marking window, type of assembly: quick fitting on the support rail, installation position any, feed-in of any kind, application areas: protection of circuits in residential and purpose buildings, and industrial systems with TNS, TT and TNC networks. In IT networks, FI / LS switches can be provided for shut-off in the event of a second Earth connection error, excluding the use in systems with TNC networks and for the protection of circuits. in which the power electronics' means of operation can cause smooth parallel or error flows with frequencies of no more than 50 / 60 Hz.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
DRCBO 4 C25 / 0.03 / 3N-A, Doepke F- / LS combination 3p + N, 25 A, 0.03 A, C-Char.Type A
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام