دسته بندی ها
کاربر سایت شوید
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Bender
تایپ کالا
:
CME420-D-2
کد سازنده
:
B93060002
ویژگیها
3-phase subvoltage possible
No
1-phase subvoltage possible
No
Tariff number
90303370
Newlec
No
Country of origin
Germany
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
HDC 16B ALU, housing (industrial connector), mounting housing, longitudinal support on the bottom, size: 6, IP65 (in a attached condition)
YBR-12.7-25BC, YBR-12.7-25BC Ty-Met stainless steel cable. Tape ware with separate heads
V1-W-YE0,3M-PVC-U-V1-G, connection cable
6SL3520-1XM02-2AF0, SINAMICS G115D, IP65 / 66 / UL type 4X, FSB, 3 AC 380-480 V,
Current relays
LINETRAXX ® CME420Product description The CME420... current relays monitor AC- flows on lower and higher steps and the current between two threshold values (window function). The flows are measured as effective values (AC). The current measured value is permanently displayed on the LC display. The measured value leading to the switching of the alarm relay is stored. Due to adjustable delay times, system-specific properties can be taken into account, for example, device-related switching flows, short-term current changes, etc. The current measurement can be done directly and indirectly via standard current converters x / 1 A, x / 5 A, x / 10 A. The CME420 series... requires a separate supply voltage. For example in sewage treatment plants • dust extraction in the wood processing function description After the supply voltage is applied, the start delay "t" starts. During this time, changes in the measured currents have no effect on the switching state of the alarm relays. The devices have two separately adjustable measuring channels (over- / undercurrent). If the measurement size exceeds the response value ("Alarm 1") or below ("Alarm 2"), the set response delays start "ton1 / 2." After the response delay is over, the alarm relays and the alarm LEDs will light up. Under or above the measurement size after switching the alarm relay the return value (response value plus hysteresis) starts the set return time "toff." After the end of "toff" the alarm relays turn back to the initial position (error memory not active). If the error storage is activated, the alarm relays remain in alarm position until the reset key is activated.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
CME420-D-2, power relay
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام