دسته بندی ها
کاربر سایت شوید
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Eltako
تایپ کالا
:
MFZ12PMD-UC
کد سازنده
:
23001006
کد EAN
:
4010312601099
ویژگیها
Function
Multifunction
Installation height
58 mm
Type of assembly
DIN rail
Number of Openers
0
Number of closers
0
Type of operation
digital with multi-function
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
3520201, protective hose SEALTITE PVC-FDA coat F.G. blue 3 / 4 -30 m
DRL 500 FS, lid with swivel bar for cable channel and cable conductor 500x3000 steel galvanized
3VA2225-5JQ32-0KA0, power switch 3VA2 IEC Frame 250 switching power class M Icu = 55kA @ 415V 3-pole, system protection ETU560, LSIG, In = 250A overload protection Ir = 100A... 250A
GS-A90210LGR, device installation channel asymmetrical 90x210x2000 steel light grey RAL 7035
Full electronic multifunction time relay, power MOSFET up to 400W
Power MOSFET with almost unlimited number of circuits up to 400W. Automatic lamps Stand-by loss only 0.3 watts. Dim to minimum brightness and maximum brightness as well as soft on / soft off when the lamp is switched on. Line installation device for assembly on DIN-EN 60715 TH35. 1 unit of division = 18mm wide, 58mm deep. Digital adjustable and fully electronic multifunction time relay for lamps up to 400W depending on the ventilation conditions. Dimmable 230V LED lamps and dimmable energy-saving lamps in addition to the lamp electronics and the dimtype. If the minimum brightness is not set to 0, then it is not switched off but is reduced to the set percentage. Up to 3600W with power added LUD12-230V on the X1 and X2 connections. Universal control voltage local 12.. 230V UC and additional universal voltage control inputs 8.. 230V UC central and central from. The control inputs are galvanically separated from the supply and switching voltage 230V. The circuit in the zero passage for the lamp sill. From 110V control voltage mica flow 5mA. Automatic electronic overload protection and overtemperature shutdown. Both the function and the times are entered with the two keys MODE and SET and displayed digitally on an LC display. When setting the time, all values can be entered within the selected time frame (0.1 to 9.9 or 1 to 99 seconds, minutes or hours). The longest time is 99 hours. 600 time settings are possible. The time (s) entered will be displayed in digital format. Adjustable: RV = relapse delay, AV = response delay, AV + = additive response delay, TI = clock switch starting with impulse, TP = clock switch starting with pause, IA = impulse-controlled response delay, IF = impulse-former, EW = switch-on, AW = switch-off, EAW = switch-off and switch-off, ARV = response and back-off delay, ARV + = additive response and back delay, ES = power switch, OV = switch-off time, OFF = switch-off time, OFF = switch-off time, OFF = power-off time, OV = power-off time, OV = power switch, OFF = power switch = time, OV = power-off For the TI, TP, IA, EAW, ARV and ARV + functions, a different second time can be entered, including with other time frames. Setting of times and functions: By pressing the MODE button, the LCDelement is selected, which is to be changed. The element in the access is flashing. By pressing the SET button, the element in the access is changed. This may be the function, time frame, time T1 or time T2 (only for TI, TP, IA, EAW, ARV and ARV +). Each input is finished with the MODE button. After the time setting with MODE no element blinks - the time relay is ready for use. With the next pressing of the MODEkey the input cycle starts from the front, all the set parameters will be maintained if they are not changed with SET. 25 seconds after the last operation and with still flashing element, the input cycle is automatically terminated and the previous changes are lost. Setting the additional parameters valid for all functions: If the MODE button is pressed for more than 2 seconds, you can enter the submenu. With the SET button, the parameter to change is selected and confirmed with MODE. With the SET button the value is entered and confirmed with MODE. After the submenu 'LED' you will automatically return to the main menu. MIN = minimum brightness in the switched off state adjustable to 0 and from 10 to 89 (%), factory setting = 0. MAX = maximum brightness in the switched on state adjustable from 10 to 99 (%), factory setting = 99. MAX shall be at least 10 steps above MIN. RMP = on-and-off pump (soft on and soft off) adjustable from 0 = 10ms to 99 = 1s, work setting = 0. LED = LED + for dimmable 230? V-LED lamps, which can not be dimmed enough in the automatic operation (phase section) and therefore must be forced on phase cut, is activated via the MODE button, work setting = LED without +. Display options of the LC display: were selected the functions ON or OFF, so that no time is shown on the OFF, but on the OFF. For all other functions, the set time (s), the function shortcut and an arrow next to ON or OFF are shown as a switching display. During the time run, the running time flashes and the remaining time is displayed. Safety in case of power failure: The set parameters are stored in an EEPROM and are therefore available immediately after a power failure.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
MFZ12PMD-UC, full electronic multifunction time relay, power MOSFET up to 400W
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام