دسته بندی ها
کاربر سایت شوید
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Euchner
تایپ کالا
:
CET3-AR-CRA-AH-50X-SH-C2333-113151
کد سازنده
:
113151
ویژگیها
Electrical connection design
Connectors
Suitable for security functions
No
Suitable for support rail assembly
No
Tariff number
85365019
Newlec
No
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
FZ24, locking insert four-channel 8mm four-way 8mm
6ES7403-1TA01-0AA0, SIMATIC S7-400 ER1 with 18 slots, steel sheet For the construction of S7-400 extension devices
F10006B300G200, STANDARD STIFT 100 MIL F100
VDOGF040MSS00.3H03STGF030MSS, connection cable, operating voltage < 50 V AC, 0.3 m, PUR, housing materials housing: TPU orange, seal: FKM, IP 65, IP 67, IP 68, IP 69K, silicone
UNICODE
Characteristics Safety switches with maintenance and integrated evaluation electronic support up to 6500 NUp to 20 switches in line crossover monitoring 2 Safety outputs (semiconductor outputs) Up to category 4 / PL e according to EN ISO 13849-1Connectors M23 (RC18) Unicode door-to-door output learning lock-in-command direction A (delivery state) lock-in set The lock-in set can be prevented from, for example, being accidentally included in the danger area of maintenance personnel. This device with the device has no auxiliary control. Safety switch The device may only be operated in conjunction with the CET-A... actuator. Important: The actuator must be ordered separately. Unicode evaluation Each actuator is a unique. The switch only detects learned actuators. Further operators can be learned. It is always only the last-trained actuator. Magnetic operating voltage DC 24 V + 10%, -15% maintenance type CET3Rest current principle maintenance by spring force. Unlocking by applying voltage to the maintenance magnet. In addition, the door position is monitored. The door alarm output OUT D is set to HIGH as soon as the actuator is above the outboard (condition: door closed, not active). The output OUT D remains set even with active maintenance. LED function indicator LED StateStatus LED DIADiagnosis LED LED 1 rd-free available LED 2 gnuntly adjustable Additional connection output (semiconductor) OUT Ddoor output RSTReset input JLearning input category according to EN ISO 13849-1By two redundant semiconductor outputs (safety outputs) with internal monitoring suitable for: category 4 / PL e according to EN ISO 13849-1Important: To reach the specified category according to EN ISO 13849-1, both safety outputs (OA and OB) must always be evaluated. The category depends on the installation position of the safety switch:
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
CET3-AR- CRA- AH-50X-SH-C2333-113151, UNICODE SAFETY SCHALTER
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام