دسته بندی ها
کاربر سایت شوید
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Euchner
تایپ کالا
:
CET3-AR-CDA-AH-50F-SH-114647
کد سازنده
:
114647
ویژگیها
Electrical connection design
Connectors
Suitable for support rail assembly
No
Suitable for security functions
No
Tariff number
85365019
Newlec
No
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
FR23U2, Schr, univers, IP55, SKII, 2050x800x400mm
DA1-12011FB-B6SC, frequency inverter, 230 V AC, 1-phase, 10.5 A, 2.2 kW, IP66 / NEMA 4X, radio interference filter, OLED- display, Local controls
NSYMPC608, PanelSeT SF / SM- front plate, full plate, 600x800mm, screwed
SLD CLIP 4CO M, support (relays), metal, for 4 changers base, D-SERIES
UNICODE
Characteristics Safety switch with maintenance and integrated evaluation electronic support up to 6500 NUp to 20 switches in line crossover monitoring 2 safety outputs (semiconductor outputs) Up to category 4 / PL e according to EN ISO 13849-1With connectors M23 (RC18) Unicode door signal output learning inlet, 75 mm long With double-ramp direction A and C (delivery state) safety switch The device may only be operated in conjunction with the control -CETA- The actuator must be ordered separately. Unicode evaluation Each actuator is a unique. The switch only detects learned actuators. Further operators can be learned. It is always only the last-trained actuator. Magnetic operating voltage DC 24 V + 10%, -15% maintenance type CET3Rest current principle maintenance by spring force. Unlocking by applying voltage to the maintenance magnet. In addition, the door position is monitored. The door alarm output OUT D is set to HIGH as soon as the actuator is above the outboard (condition: door closed, not active). The output OUT D remains set even with active maintenance. LED function indicator LED StateStatus LED DIADiagnosis LED LED 1 rd-free available LED 2 gnuntly adjustable Additional connection output (semiconductor) OUT Ddoor output RSTReset input JLearning input category according to EN ISO 13849-1By two redundant semiconductor outputs (safety outputs) with internal monitoring suitable for: category 4 / PL e according to EN ISO 13849-1Important: To reach the specified category according to EN ISO 13849-1, both safety outputs (OA and OB) must always be evaluated. The category depends on the installation position of the safety switch:
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
CET3-AR-CDA-AH-50F-SH-114647, UNICODE SAFETY SCHALTER
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام