جستجوی کالا ...

logo
Picture of ["Q1A 5 (60) A, 1x230V, MID, ET, LB, AC meter for delivery and reference 0.01-5 (60) A, MID"]

Q1A 5 (60) A, 1x230V, MID, ET, LB, AC meter for delivery and reference 0.01-5 (60) A, MID

وضعیت

:

موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته

برند

:

NZR

تایپ کالا

:

Q1A 5(60)A,1x230V,MID,ET,LB

کد سازنده

:

63321115

کد EAN

:

4048652102822

ویژگی‌ها

Alloy

Yes

EDL40 signature

No

Width in units

10

Number of posts

8

Type of assembly

Installation

Reverse lock

No

قیمت

:

استعلام

حداقل قابل خرید

:

1 عدد

قابل پرداخت

:

استعلام

معرفی

AC current meter for delivery and reference 0.01-5 (60) A, MID

Q1A, 5 (60) A, reference and delivery, with D0output, 1-tariff, MID Electronic AC meter for direct connection, for 2-circuit networks, with D0output, 1-tariff, for both energy directions MID consistent, for counter-cross assembly, functionality according to FNN load specification, EDL V1.2, extensible to the Intelligent Measurement System, manipulative, resistant to electromagnetic interference fields (EMV), for example, for strong permanent magnets, for example, in case of overload, with high-pressure, for example. Very well suited for photovoltaic systems. The special measurement method allows a frequency-independent power measurement up to > 150kHz AC with an accuracy < 0.2%. This ensures an exact identification of electronic consumers and feed-in systems, e.g. DC / AC converters of PV- systems. Very low losses and thus low self-heating. Rolling info line, content can be configured via MSB interface. Operation for final consumers by means of optical call button with PIN protection and Tacho zero position. Current power (W) .Historical energy values (kWh) for day, week, month, year, storage depth over two years. Bidirectional MSB interface (D0) protocol according to SML 1.04. Functionality according to FNN Fastenheit EDL V1.2.Every second transmission of the ID number, counter stands, phase and sum power. Unidirectional INFOinterface, protocol according to SML 1.04. Functionality according to FNN specification EDL V1.2. Expandable by plug-in modules. As an extension to the intelligent measuring system according to the MsbG. For other communication, additional functions, etc.. power supply of the modules via terminals 7 / 11. Technical data System 4-conductor also approved as 2-conductor AC meter, voltage (U) 1x230VCurrent (I) 5 (60) A, frequency (f) 50 Hz, accuracy (wire) A, own consumption (U) < 0,6 VA per phase (< 2,5VA), own consumption (I) < 7,5mW at I < 1,1W at 60A, temperature range (Tb) -25 to + 55 ° C, protection class (housing) IP, weight of about 0.55 kg, dimensions (B x H), type 1-1-1V, 1mm (NZU), type 1-1-1V, 1V, 1mm (1), 1mm (1-1), 1mm (1), 1mm (1-1-1), 1mm (1-1, 1mm)

مشخصات کالا

دیدگاه کاربران

شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.

دیدگاه خود را ثبت کنید

Q1A 5 (60) A, 1x230V, MID, ET, LB, AC meter for delivery and reference 0.01-5 (60) A, MID

قیمت

:

استعلام

حداقل قابل خرید

:

1 عدد

قابل پرداخت

:

استعلام