دسته بندی ها
کاربر سایت شوید
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Doepke Schaltgeräte
تایپ کالا
:
DRCBO 4 B32/0,03/3N-A
کد سازنده
:
09945107
کد EAN
:
4014712266582
ویژگیها
Polar number (total)
4
Current
32 A
Fault current type
A
Action characteristics
B
Uimp
4 kV
Upholding
No
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
ZB55S, numerator, univ. Z, 1400x1300x205mm, SKII
3VA2463-5JQ32-0AD0, power switch 3VA2 IEC Frame 630 switching power class M Icu = 55kA @ 415V 3-pole, system protection ETU560, LSIG, In = 630A overload protection Ir = 250A... 630A
2016-7601, 2-conductor distribution feed-in terminal 16 mm ² grey
3VA1112-5MH32-0KA0, power switch 3VA1 IEC Frame 160 switching power class M Icu = 55kA @ 415V 3-pole, starter protection TM120M, AM, In = 125A without overload protection Short circuit
Doepke FI / LS combination 3p + N, 32 A, 0.03 A, B-Char.Type A
RCBO combines error current and control switch in one device (FI / LS combination). They protect people from flaws and systems from short circuit and overload. DRCBO 4 has a rated power of 6 kA. In addition to the triggered display, they also offer a label window. Type A switches are pulse and AC sensitive. This function is power independent. Switches with the trigger characteristic B are the standard protection for light and socket circuits. Standard switches are for circuits with a measurement voltage of 230 V or 400 V and a rated frequency of 50 Hz. Characteristics: pulse and AC-sensitive, power-independent trigger, low size for all measuring currents, switching position display, separate display of the trigger floor, pull-in terminals with a wide clamp-section area on both sides of the connection, neutral ladder on the right, marking window, type of assembly: quick fitting on the support rail, installation position any, feed-in of any kind, application areas: protection of circuits in residential and purpose buildings, and industrial systems with TNS, TT and TNC networks. In IT networks, FI / LS switches can be provided for shut-off in the event of a second Earth connection error, excluding the use in systems with TNC networks and for the protection of circuits. in which the power electronics' means of operation can cause smooth parallel or error flows with frequencies of no more than 50 / 60 Hz.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
DRCBO 4 B32 / 0.03 / 3N-A, Doepke F- / LS combination 3p + N, 32 A, 0.03 A, B-Char.Type A
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام