Legrand
تایپ کالا
:
415921
کد سازنده
:
415921
کد EAN
:
3414971169364
ویژگیها
Measurement power according to EN 61009
6 kA
Measurement power according to EN 60898
6 kA
Polar number
2
Degree of pollution
2
Action characteristics
B
On-line neutral conductor
Yes
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
Z17110, counter place 3Pkt 1Z with clamping stone 5-pole, BxH: 250x1050mm
083107- 057023, STROMABTER 0831 5P1PE 80A REV S2 LE
3VA2063-5HN32-0CC0, power switch 3VA2 IEC Frame 100 switching power class M Icu = 55kA @ 415V 3.
TK PC 1813-11-tm, empty housing, protection type IP66, impact resistance IK08, protection class II, Ui 690V AC, measurement insulation voltage 1000V DC, UL, DLG, DNV, halogen-free
DX3 AFDD fire protection switch with LS switch B13 A, 1P + NR, 6kA, 230VAC, 2TE
Legrand fire protection switch DX3 STOP ARC. To EN 62606, VDE 0665-10, EN 60898-1, VDE 0641-11. AFDD with LS- switch, 1-pole with connected neutral conductor, LS- protection switch: B-characteristic, Rated current In 13 A, Rating power Icn 6 kA according to EN 60898-1, Rating voltage Un 230 VAC, Rating frequency 50 Hz, Energy limitation class 3, Fastening to Hut profile EN 60715 by fast-moving fasteners, clear information at the front of each device, clear switching position display red / green at the control lever, with the right-hand front, Fastable with the right-end, Installation of auxiliary equipment possible. The fire protection switch DX3 STOP ARC is a combination of fault light arc protection device AFDD and line protection switch. The single-pole protected and two-polated AFDD with the control switch provides a safe all-pole shutdown for the following error images: overload, short circuit, parallel and serial error light sheets. With LED state indicator for the recognition of the operating status, message for the visual detection in case of an error-light arc. The self-monitoring of the AFD unit is carried out via an internal daily self-test. For example, the causes of the formation of fault light arc are: damaged conductor insulation by nails, screws or holes, squeezed cables or lines, loose or faulty clamping points in sockets or screw connections.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
415921, DX3 AFDD fire protection switch with LS switch B13 A, 1P + NR, 6kA, 230VAC, 2TE