دسته بندی ها
کاربر سایت شوید
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Eltako
تایپ کالا
:
FSR71NP-230V
کد سازنده
:
30100865
کد EAN
:
4010312316221
ویژگیها
Suitable for dimmer
No
Suitable for pulse printers
Yes
Suitable for roller shutters
No
Suitable for blinds
No
Suitable for blinds / shutters
No
Suitable for switches
Yes
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
Additionally available packaging sizes: 1 / 5
Power shock control relais 1 Clasp non-potential-free 16A / 250V AC, 230V LED lamps up to 400W, filament lamps 2000W. With light-rate control via PC or with radio-actuators. Encrypted radio, bidirectional radio and repeater function can be switched on. Stand-by loss only 0.8 watts. Assembly into the 230V power supply line, for example in intermediate ceilings and lamps. 166mm long, 46mm wide and 31mm high. With cable train load. In the event of a failure of the supply voltage, the switching state is maintained. In the case of a recurring supply voltage, it is defined to be off. Scene control: With one of the four control signals of a double-tailed button, several FSR71NP can be switched on or off to one scene. Central commands are sent via the app with a controller. To do this, learn one or more FSR71NP via the respective app. The switches are used to learn the buttons and test the device if necessary. For normal operation, the middle and lower switches are then set to AUTO. With the upper switch, the EW- time (0- 120 seconds) for relays or RV-time (0- 120 minutes) for current-impact switches is set. If radio-motion-brightness sensors FBH (Master) and / or FBH (Slave) are learned, the switch is set with the upper switch, at which the lighting switches on or off. The upper switch settings according to the operating instructions. If the radio-brightness sensors are learned, the switch shaft is set with the upper switch, at which the lighting switches on or off depending on the brightness (from about 0lux in position 0 to about 50lux in position 120). A hysteresis of about 300lux between the on and off is fixed. An additional set of RV time is not observed. Only one FBH (Master) or FAH can be learned. If radio window door contacts FTK or window access sensor FFG7B are learned, different functions can be set with the average switch in positions AUTO 1 to AUTO 4 and can be connected to a maximum of 116 FTK: AUTO 1 = window to, then output is active. AUTO 2 = open window, then output active. In the positions AUTO 3 and AUTO 4 the trained FTC are automatically linked. In the case of AUTO 3, all FTC must be closed to close the working contact (e.g. for climate control). In the case of AUTO 4, an open FTC is sufficient to close the working contact (e.g. for alarm or switch on the power supply of a wind outlet). After a power failure, the connection is made by a new signal from the FTC or restored after 15 minutes at the next status message. An additional set of RV time is not observed. If water sensors are learned, different functions can be set with the mean turning switch in the positions AUTO 1 to AUTO 4. AUTO 1 = no water, then work contact closed. AUTO 2 = water, then working contact closed. In the positions AUTO 3 and AUTO 4, the water sensors on a channel are automatically connected. In the case of AUTO 3, all water sensors must not have reported any water to close the working contact. The working contact opens when a water sensor reports water. In the case of AUTO 4, when a water sensor reports water, the working contact only opens when all water sensors have not reported water. An additional set of RV time is not observed. The LED under the upper switch accompanies the learning process according to the operating instructions and displays control commands in operation by a short flash.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
FSR71NP -230V, radio actor current shock control relays, 1 closing 16A
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام