ویژگیها
Bus system KNX
No
Radio bus system
Yes
Bus system LON
No
Powernet bus system
No
Other bus systems
without
Bus system KNX-RF (radio)
No
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
Additionally available packaging sizes: 1 / 10 / 100
Display control clock with 8 channels for the ELTAKO- RS485- bus. With Astrofunction. Stand-by loss only 0.1 watts. Line installation device for assembly on DIN-EN 60715 TH35. 1 unit of division = 18mm wide, 58mm deep. Connection to the ELTAKO- RS485- bus, cross-wiring bus and power supply with plug-in bridge. For the function of the FSU14 control tube, a device address is required from the FAM14 radio antenna module, as described in the operating manual. The switching commands of the channels can be learned in bus actuators and in radio actuators. Up to 60 control tube storage places are freely distributed on the channels. With date and automatic summer time / winter time conversion. Power reserve without battery approx. 20 days. Each storage space can be occupied either with the astrofunction (automatic switching after sunrise or sunset) or the time function. The on / off time Astro can be moved ± 2 hours. In addition, a time shift of up to ± 2 hours, influenced by the solenoids, can be entered. The switch clock is set with the keys MODE and SET and the settings can be locked. Set language: After each setting of the supply voltage, the language can be selected and confirmed with SET within 10 seconds. D = German, GB = English, F = French, IT = Italian and ES = Spanish. The normal display will then appear: day, time, day and month. Quick run: In the following settings, the numbers run up quickly when the input key is pressed longer. Let go and press again longer changes the direction. Set Time: Press MODE and use SET to search for UHR and select with MODE. At S with SET, select the hour and confirm with MODE. Just as with M. Set date: Press MODE and use SET to search for DAT and select with MODE. At J with SET select the year and confirm with MODE. As with M as month and T as day. As the last setting in the order, MO (day of the week) blinks. This can be set with SET. From the production week 08 / 17, the time (hour and minute) and the day of the week can be activated. It is possible to learn on / off, off and off mode. Set position coordinates (if the Astrofunction is desired): Press MODE and search for the POS function with SET and select with MODE. For BRT with SET, select the latitude and confirm with MODE. Also with LAE, select the length and confirm with MODE. Now with GMT with SET select the time zone and confirm with MODE. If desired, WSW (winter solstice) and SSW (summer solstice) can now enter a time shift of up to ± 2 hours for all channels. Summer / Winter time conversion: Press MODE and use SET to search for SWZ and select with MODE. Now you can switch between ON and OFF with SET. If ONE has been selected, the switch-over is automatic. Lock settings: Press MODE and SET together and lock with SET at LCK. This is displayed by an arrow next to the lock symbol. Unlock settings: Press MODE and SET together for 2 seconds and unlock with SET at UNL. Line-bound central control: T1 / T2 and T3 / T2 terminals can be connected to central control switches. Set mode of operation: Press MODE and use SET to search for INT and select with MODE. For KNL, select the channel with SET and confirm with MODE. SET can be used to switch between ZEA (automatic with central control), AUT (automatic), ON (with priority) or OFF (with priority). If ON or OFF is confirmed with MODE, the corresponding telegram is sent immediately. If the switching state is to change automatically again when a time program becomes active, the channel must be set to ZEA or AUT again. If MODE is pressed for more than 2 seconds, the normal display will appear. Learn channels in actuators: Press MODE and use SET to search for LRN and select with MODE. For KNL with SET, select the channel and confirm with MODE. For more information, see the user manual. Enter switching programs: Press MODE and select one of the 60 storage places from P01 to P60 in the PRG function with MODE and SET. For more information, see the user manual. When the random mode is switched on, all switching times of all channels are randomly moved by up to 15 minutes. Switch-on times to earlier and off times to later. For more information, see the user manual.
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
FSU14, RS485bus display clock
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام