دسته بندی ها
کاربر سایت شوید
وضعیت
:
موجود در انبار اروپا - زمان تحویل 4 تا 6 هفته
برند
:
Dimplex
تایپ کالا
:
LA 1118CP
کد سازنده
:
LA1118CP
ویژگیها
Tariff number
84186100
Newlec
No
Country of origin
Germany
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام
مشاهده جزییات فنی کالا :
31220-LA1118CP _ L / W heat pump to LA 1118CP (not individually)
Heat pump for heating and cooling with inverter control for external position with wall-mounted heat pump manager WPM Touch with touch display. Sound-optimized by flow-optimized air guidance with capped compressor space, axial fan for naturally quiet air noise and free oscillating compressor base for body sound decoupling. High power (COP) by high-performance evaporator, electronic expansion valve, EC fan for the adjustment of the air volume current, self-optimising performance control and natural refrigerant R290. Maximum operational safety by sensory monitoring of the cooling circuit with self-optimising seawater, additional safety is provided by the sophisticated safety concept with minimum distances (1 meter) for the use of the natural refrigerant R290. The integrated flow sensor and the heat count to display the calculated amount of heat for heating and hot water production at the heat pump manager round off the topic of operational safety. Simple and fast assembly by wall-close installation with a minimum wall-distance of 0.3 m on the intake side, a housing concept optimized for the outside position and the possibility to connect the heat pump from the bottom and back. Universal design with flexible expansion possibilities for: bivalent or bivalent regenerative operation unmixed and mixed heating / cooling circuit room temperature control via smart RTC (special accessories) use load variable tariffs (SG Ready) At an outside temperature of -10 ° C a maximum flow temperature of 65 ° C can be reached. In the case of silent cooling via surface heating / cooling systems, the room temperature controller with moisture sensor (RTM Econ) and a mixed heating circuit is required to regulate the flow temperature in accordance with the air temperature and humidity of a reference space. Embedded dirt collector and sensory flow measurement to ensure the minimum heating water flow rate. integrated forward and return sensors; External sensor (standard NTC-2) in delivery. The electrical connection between the control to be mounted in the building and the external unit is made via a 2-wheel data cable not included (e.g. LiYY 2x0.6 mm ² or J-Y (ST) Y.. LG2x2x0.8mm ²). Side parts and lid anthracite grey structured (similar to RAL 7016), front coverings grey aluminium structured (similar to RAL 9007).
شما هم می توانید دیدگاه خود را درباره این کالا ثبت کنید.
دیدگاه خود را ثبت کنید
LA 1118CP, 31220-LA1118CP _ L / W heat pump to LA 1118CP (not individually)
قیمت
:
استعلام
حداقل قابل خرید
:
1 عدد
قابل پرداخت
:
استعلام